Engineer programming via the browser
15
X-BUS
201
Siemens AB
A6V10276959
Security Products
18.11.2011
For naming and identifying:
In loop configuration, each expander is numbered consecutively from the first
(expander connected to the 1A 1B on the controller) to the last (expander
connected to the 2A 2B on the controller).
Example for SPC63xx: Expanders, when numbered 1 through 63, are allocated
zones (in groupings of 8) in subsequent identities of 1 to 512 (the greatest
number in zone identification is 512). Therefore, any expander named or
identified by a number greater than 63 has no allocated zones.
Expander ID
ID of the door controller set with the rotary switches.
Type
Type of the door controller.
S/N
Serial number of the door controller.
Description
Description of the door controller..
Door I/O 1
If a door is assigned to the door I/O, select the corresponding door number.
If the two inputs and outputs are configurable, select Zones / Outputs.
If a door number is selected for the door I/O, the door settings can be
changed by clicking on the edit button. This is equal to Settings > Doors.
If Zones / Options is selected, the two zones and the one output can be
configured by clicking the edit button.
Door I/O 2
Profile 1
For readers with a green and a red LED.
Profile 2
For SIEMENS readers with a yellow LED (AR618X).
Profile 3
Profile 3 is used with HID readers that send a PIN to the panel as a card reading
with a predefined site code (0 )
Profile 4
Profile 4 is used with HID readers that send a PIN to the panel as a card reading
with a predefined site code (255 ).