Appendix
Domestic, Commercial and Financial mode default settings
272
Siemens AB
A6V10276959
Security Products
18.11.2011
30 h
312 mA
287 mA
182 mA
157 mA
Values listed as N / A indicate that the selected battery does not have the capacity
to power the minimum load of just the SPC controller for the given standby time.
See page [270] for maximum load of devices and modules.
Only sealed cell valve regulated battery types to be used.
For EN compliance the supplied current needs to be supported by the battery for
required stand by time.
21.5 Domestic, Commercial and Financial mode default
settings
This table gives the default zone name and types on the controller for each mode
of operation. All zones on connected expanders are be categorized as unused until
explicitly configured by the installation engineer.
Feature
Domestic mode
Commercial mode
Financial mode
Zone Names
Controller - Zone 1
Front door
Front door
Front door
Controller - Zone 2
Sitting room
Window 1
Window 1
Controller - Zone 3
Kitchen
Window 2
Window 2
Controller - Zone 4
Upstairs front
PIR 1
PIR 1
Controller - Zone 5
Upstairs rear
PIR 2
PIR 2
Controller - Zone 6
PIR hallway
Fire exit
Fire exit
Controller - Zone 7
PIR landing
Fire alarm
Fire alarm
Controller - Zone 8
Panic button
Panic button
Panic button
Zone Types
Controller - Zone 1
ENTRY/EXIT
ENTRY/EXIT
ENTRY/EXIT
Controller - Zone 2
ALARM
ALARM
ALARM
Controller - Zone 3
ALARM
ALARM
ALARM
Controller - Zone 4
ALARM
ALARM
ALARM
Controller - Zone 5
ALARM
ALARM
ALARM
Controller - Zone 6
ALARM
FIRE EXIT
ALARM
Controller - Zone 7
ALARM
FIRE
ALARM
Controller - Zone 8
PANIC
PANIC
ALARM