Engineer programming via the browser
15
Configuring zones, doors and areas
173
Siemens AB
A6V10276959
Security Products
18.11.2011
15.8.2.6 All Okay
All Okay Required
If selected, user must confirm ‘All okay’ input or silent alarm is
generated. See Editing a Zone [ 165] for details on configuring an ‘All
Okay’ zone input.
All Okay Time
Time (in seconds) in which ‘All okay’ must be confirmed before alarm is
raised. (Range 1 999 seconds)
All Okay Event
Select the event type to be sent when the ‘All okay’ timer expires.
Options are Panic (Silent), Panic and Duress.
15.8.2.7 Reporting
The Reporting configuration settings are applicable for Standard Areas in
Commercial and Financial installations only and are only relevant if a calendar
has been selected. (See Schedule [170] section)
These settings enable a report to be sent to the Control Centre or nominated
personnel if the panel is Set or Unset outside scheduled calendar times.
Early to Set
Enables a report to be sent if the panel is manually Fullset before a
scheduled Set and before the number of minutes entered in the
Timer field.
Late to Set
Enables a report to be sent if the panel is manually Fullset after a
scheduled Set and after the number of minutes entered in the Timer
field.
Early to Unset
Enables a report to be sent if the panel is manually Unset before a
scheduled Unset and before the number of minutes entered in the