Enter the minutes how long after the last configuration change the
panel should contact the server to report its configuration ( min: 1,
max.: 120 ).
Enter the Hostname, URL or IP address of the SPC Safe server (e.g
the IP address of your PC).
15.12.7 Alarm Reporting Centres (ARCs)
The SPC panel has the facility to communicate information to a remote receiving
station when a specific alarm event on the panel has occurred.
These Alarm Reporting Centres must be configured on the panel to allow this
remote communication to operate.
15.12.7.1 SIA codes
SIA (Security Industries Association) codes are an industry standard format for
reporting detailed information on alarm events to a remote central station. Each
code consists of a 2 letter identifier that is interpreted by the central station
according to the list below.
An address field (zone or user number) is also included with some of the codes
listed to give more accurate information on the event; e.g. the SIA code BA5 refers
to a burglary alarm event on Zone 5.
For a full listing of codes, see page [➙ 273].
15.12.7.2 Adding / Editing an ARC
A PSTN or GSM modem is installed and functioning correctly.