Engineer programming via the browser
15
Panel status
127
Siemens AB
A6V10276959
Security Products
18.11.2011
1. Click the Log button.
2. See table below for further information.
Date/Time
The date and time of the logged event.
Receiver
The wireless receiver location, i.e. wireless
module mounted on the keypad, controller or
wireless expander.
Signal
The signal strength received from the sensor
(01=low, 09=high).
Status
The physical status of the sensor.
Battery
The status of the battery connected to the sensor
(OK, Fault).
15.4.7 X-Bus
The status of the different X-Bus devices can be seen. On opening the page, all
detected keypads are listed.
In order to see all detected expanders or door controllers:
Select one of the following types from the dropdown list.
Expanders (for programming expanders see page [➙ 195]).
Keypads (for programming keypads see page [➙ 190]).
Door controllers (for programming door controllers see page [200]).
Further status and options
1. Click any of the keypad/expander identifying parameters (ID, description, type,
serial number).
2. Further status and options for keypads/expanders provide the following:
- Communication: The physical status (OK, Fault) and the programmed
status (OK, Isolated, Inhibited) of the keypad cable connection to the
expander.
- Cabinet Tamper: The physical and programmed status of the expander
cabinet tamper.
- PACE: Applies only to Keypads with a PACE receiver installed.