15
Engineer programming via the browser
Configuring zones, doors and areas
170
Siemens AB
A6V10276959
Security Products
18.11.2011
Linked Areas
Click on the areas that you wish to link to this area.
15.8.2.4 Schedule
Configure scheduling with the following settings:
Calander
Select a calendar to control scheduling.
Unset
Select if area should automatically Unset as
per the time specified in the selected
calendar.
Fullset
Select this option to Fullset the area as per
the time specified in the selected Calendar.
The area will also set when the Unset
Duration or Delay Interval has elapsed (See
Setting and Unsetting [ 170] section). If
the Unset Duration overlaps the scheduled
time, the area will use the calendar settings.
Time Locked
Select this option to time lock the area as
per the selected Calendar.
Vault Access
Enter the number of minutes (0 – 120) to
activate this timer at the end of a Time
Locked Unset period. If the area is not unset
after this timer expires, the area cannot be
unset until the start of the next Time Locked
Unset period.
15.8.2.5 Setting/Unsetting