Wiring of mains cable to the controller
282
Siemens AB
A6V10276959
Security Products
18.11.2011
21.12.3 Engineer Access
An Engineer can only access the system if permitted by a ‘Manager’ user type (see
‘Engineerattribute in User Rights [131]) and only for a specified time duration
(see ‘Engineer Accessin Timers [160]).
21.12.4 Keypad User Logoff
If no keys are pressed on a keypad for a specific duration (see ‘Keypad Timeoutin
Timers [ 79]), the user is automatically logged off.
21.13 Wiring of mains cable to the controller
Requirements:
A readily accessible approved disconnect device must be incorporated in the
building installation wiring. This must disconnect both phases at the same time.
Acceptable devices are switches, circuit breakers, or similar devices
Minimum size conductor used for connecting mains is 1.5 mm square
The circuit breakers must have a maximum rating of 16 A
The mains cable is secured to the metal V shaped bend in the base plate via a tie
wrap such that the metal bend is between the cable and the tie wrap. Ensure that
the tie wrap is applied to the supplementary insulation of the mains cable i.e. the
outer PVC cable sleeve. The tie wrap must be pulled extremely tightly such that
when the cable is tugged there is no movement in the cable relative to the tie wrap.
The Protective Earthing conductor should be fitted to the terminal block in such a
way that if the mains cable should slip in its anchorage, placing a strain on the
conductors, the Protective Earthing conductor will be the last item to take the
strain.
The mains cable must be an approved type and marked HO5 VV-F or HO5 VVH2-
F2.
The plastic tie wrap must be flammability rated V-1.
21.14 Maintenance controller
The system should be serviced in accordance with the service schedule that is in
place. The only replaceable parts on the controller are the mains fuse, standby
battery and the time & date battery (PCB mounted).
It is recommended that during a service the following be checked:
The Event Log to check if any standby battery tests have failed since last
service if standby battery tests have failed then the standby battery should be
checked.
The standby battery should be replaced as per the servicing schedule to
ensure that it has sufficient capacity to hold the system up for the time defined
in the system design. The battery should be physically inspected for any
deformation of the casing or any sign of leakage; if any of these conditions
exist the battery should be immediately replaced.