Starting the system
12
Configuring 868 MHz wireless FOB devices
73
Siemens AB
A6V10276959
Security Products
18.11.2011
2
Fullset
4
Partset
Number of RF fobs per user: Only one fob device can be programmed for each
user. To change fob devices among users, repeat the programming procedure for
any new devices. Old fob devices become available for use by different users.
Force setting with the RF fob: It is NOT possible to force set the system with an
RF fob even if the user assigned to the fob has the ability to force set. Force
setting is only possible at the keypad.
12.6.1 Clearing alerts using the wireless FOB Device
Alerts on the SPC system are normally cleared using the keypad RESTORE
option. Clearing alerts can also be performed by using the wireless fob device.
When an active alert is displayed on the keypad when the system is UNSET, the
alert can be cleared or restored by pressing the UNSET key on the wireless fob
five seconds after the system has been unset.
To enable this functionality, the KEYFOB RESTORE variable must be enabled:
1. Scroll to FULL ENGINEER > VARIABLES.
2. Press SELECT.
3. Scroll to KEYFOB RESTORE and press SELECT.
4. Toggle the setting to ENABLED and press SAVE.