19 Audio/Video Verification
To set up Audio/Video Verification on an SPC system:
1. Install and configure Audio Expander (s)
2. Install and configure Video Camera(s).
3. Install and configure Audio Equipment.
4. Configure Verification Zone(s).
5. Test audio playback from verification zones.
6. Assign Verification Zone(s) to physical zone(s).
7. Configure Verification Settings.
8. View images from verification zones in web browser or SPC Pro.
Keypads and access control may be disabled for several minutes while sending
an audio file to the panel, depending on the size of the file.
19.1 Configuring Video
Overview
Cameras are used for video verification. The SPC panel supports a maximum of
four cameras. Only IP cameras are supported and the panel must have an
Ethernet port.
Cameras must not be shared with other CCTV applications.
Cameras can only be configured with the web browser or SPC Pro. Configuration
with the keypad is not supported. SPC Pro provides an easier method of
configuration and is recommended.
The panel supports two camera resolutions:
320X240
This setting is recommended if you want to view images on the browser)
640X480 (with some restrictions).
The following cameras are supported in addition to other generic cameras:
Siemens CCIC1410 (1/4” VGA IP Colour Camera)
Siemens CFMC1315 (1/3” 1.3 MP Indoor Dome Colour Camera)
A command string is available as a default to access configuration details for the
above cameras directly. Other generic IP cameras require a command string to be
entered manually.
Adding Camera
1. Select Settings>Verification>Video.