Engineer programming via the browser
15
Configuring zones, doors and areas
169
Siemens AB
A6V10276959
Security Products
18.11.2011
access option, the buzzer will sound for the entry time period
when the PIR sensor is activated thereby warning the user
that the alarm will activate if no action is taken.
Partset Exit/Entry:
Tick the relevant checkbox to change the behaviour of
entry/exit zones to alarm zones when in Partset A or B mode.
This feature is useful for a domestic installation when the
system has been set in partset mode. If the user partsets the
system at night he/she may wish the alarm to activate
immediately if the front or back door is opened during the
night.
Partset Local:
Tick the relevant checkbox to restrict the reporting of alarms
in Partset Mode to local reporting only (No remote reporting).
15.8.2.3 Linked Areas
This section enables you to link areas for setting and unsetting purposes:
Fullset
Fullset this area when all linked areas are Fullset.
Fullset All
Fullset all areas when this area is Fullset.
Prevent Fullset
Prevent this area from Fullset if all linked areas are Fullset.
Prevent Fullset All
Prevent linked areas from Fullset if this area is not Fullset.
Unset
Unset this area when all linked areas are Unset.
Unset All
Unset all areas when this area is Unset.
Prevent Unset
Prevent this area from Unset if any linked areas are Fullset.
Prevent Unset All
Prevent linked areas from Unset if this area is Fullset.