Siemens SPCK421 Especificaciones Pagina 179

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 296
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 178
Engineer programming via the browser
15
Configuring zones, doors and areas
179
Siemens AB
A6V10276959
Security Products
18.11.2011
Attribute
Description
door group.
In this mode, cardholders must use their access card to
gain entry into and exit from a defined door group. If a valid
cardholder has presented his access card to enter a door
group and not presented the card to exit it, the cardholder is
in breach of the Anti-Passback rules. Next time the
cardholder attempts to enter the same door group, a hard
Anti-Passback alarm will be raised and the cardholder will
not be permitted entry to the door group.
Soft Passback*
Anti-passback violations are only logged. All doors must
have entry and exit readers and must be assigned to a door
group.
In this mode, cardholders must use their access card to
gain entry to and exit from a defined door group. If a valid
cardholder has presented his access card to enter a door
group and not presented the card to exit it, the cardholder is
in breach of the Anti-Passback rules. Next time the
cardholder attempts to enter the same door group, a Soft
Anti-Passback alarm will be raised. However, the
cardholder will still be permitted entry to the door group.
Custodian*
The custodian feature allows a card holder with custodian
right (the custodian) to give other cardholders (non-
custodians) access to the room.
The custodian must be the first to enter the room. The non-
custodians are only allowed to enter if the custodian is in
the room. The custodian will not be allowed to exit until all
non-custodians have left the room.
Door sounder
Door controller PCB mounted sounder sounds on door
alarms.
Ignore Forced
Door forced open is not processed.
Interlock*
Only one door in an area will be allowed open at a time.
Requires Door Group.
Setting Prefix
Authorisation with prefix (A,B,* or #) key to set system
* Require door group
Door timers
Timer
Min.
Max.
Description
Access granted
1 s
255 s
The time the lock will remain open
after granting access.
Access deny
1 s
255 s
The duration after which the
controller will be ready to read the
next event after a invalid event.
Door open
1 s
255 s
Duration within which the door
must be closed to prevent a “door
open too long alarm.
Door left open
1 min
180 min
Duration within which the door
must be closed to prevent a “door
left open” alarm.
Vista de pagina 178