Siemens SPCK421 Especificaciones Pagina 266

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 296
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 265
20
Seismic Sensors
Seismic Sensor Testing
266
Siemens AB
A6V10276959
Security Products
18.11.2011
If all areas or an area group or a single area are selected to be set, and a seismic
test fails, then SEISMIC FAIL will be displayed. Pressing Return displays a list of
the failed zones which can be scrolled through using the up and down arrow keys.
Depending on the Inhibit settings for the failed seismic zones and your user profile,
the following can occur:
If all of the seismic zones that failed the test have the Inhibit attribute set, and
your user profile user is configured with the Inhibit right:
1. Press Return on any of the failed zones.
The message “FORCE SET ALL?is displayed.
2. Press Return again to inhibit all seismic zones that failed the test.
(Alternatively, go back to the previous menu.)
Setting proceeds as normal.
If some of the seismic zones that failed the test do not have the Inhibit attribute
set or your user profile user does not have the Inhibit right:
Press Return.
The message ‘FAIL TO SET’ will be displayed and no areas will be set.
There is no automatic seismic test for areas that are auto-set for any reason (for
example, areas activated by a calendar or trigger). Likewise there is no automatic
seismic test when the system is set with SPC Com, with SPC Pro or the browser.
However, there is an automatic seismic test when a virtual keypad is used with
SPC Com or SPC Pro.
No event is reported if seismic testing on set fails.
The periodic automatic system test timer restarts after a test is performed after
setting.
20.1.3 Manually Testing Sensors
To manually test sensors, select the TEST>SEISMIC TEST option from the TEST
menu on the keypad.
A seismic manual test with the keypad can be done by the engineer in Full
Engineer mode, and also by a user of type Manager or type Standard:
An engineer is able to test all sensors in all areas configured in the system
using any keypad.
A user is able to test only the sensors in areas that are both assigned to him
and to the particular keypad he is using.
To perform a seismic test in Engineer mode, select FULL ENGINEER TEST
SEISMIC TEST
To perform a seismic test in User mode, select MENUS TEST SEISMIC TEST
Note: The following instructions apply to both engineer and user modes but please
note that only a subset of options may be available to a user.
The following options are available in the SEISMIC TEST menu:
TEST ALL AREAS
Tests seismic zones in all available areas if there is more than one area that
contains seismic zones.
AREA NAME
The names of the areas containing seismic zones are listed individually. When
a specific area is selected, the following options are available:
Vista de pagina 265