21
Appendix
Compliance with INCERT Approvals
294
Siemens AB
A6V10276959
Security Products
18.11.2011
Selecting Grade 2 or Grade 3 selects EN50131 compliance plus any additional
INCERT requirements:
Only an engineer can restore a tamper. For INCERT, this applies across all
grades.
This is normally only a requirement for Grade III En50131.
A tamper on an Inhibited / Isolated zone must be sent to an ARC and displayed
to the user.
For INCERT, tampers are processed for isolated zones. On all other standard
variations, tampers are ignored on isolated zones.
Hardware Requirements
The minimum battery capacity for SPC42xx/43xx/52xx/53xx/63xx is 10 Ah / 12
V. If a 10 Ah battery is used, then the battery is biased to the left of the cabinet
and the bottom flap is bent to meet the battery.
Fit jumper (J12) on the battery selector for 17/10 Ah battery use and remove for
7 Ah battery.
The amount of current from Aux output using a 10 Ah battery for
SPC42xx/SPC52xx is:
Vista de pagina 293