Siemens SPCK421 Especificaciones Pagina 107

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 296
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 106
Engineer programming via the keypad
14
TEST
107
Siemens AB
A6V10276959
Security Products
18.11.2011
14.11.6 AUDIBLE OPTIONS
The audible options are applied as indicators within a walk test.
To set the audible options:
1. Scroll to AUDIBLE OPTIONS.
2. Press SELECT.
3. Scroll to one of the following options: ALL, INT BELL, EXT BELL, KEYPAD
4. Press SAVE.
5. Press BACK to exit.
14.11.7 WPA TEST
NOTICE
This test can be only be performed by an engineer or user that has a ‘WPA Test’
right assigned to them. See User rights [ 131]
To test the WPA from the keypad:
1. Scroll to WPA TEST and press SELECT.
2. When prompted with ACTIVATE WPA, press the three buttons simultaneously
on the WPA.
If the test succeeded, a WPA
n
OK message will be shown where n is the
number of WPA being tested.
1. Repeat the test if required.
2. Press BACK or X to end the test.
See also
User rights [➙ 131]
14.11.8 SEISMIC TEST
To perform a seismic test:
1. Scroll to TEST > SEISMIC TEST.
2. Press SELECT.
3. Select TEST ALL AREAS, or select an individual area to test.
4. If you select an individual area to test, you can select either TEST ALL ZONES
or select a specific seismic zone to test.
The message SEISMIC TEST is display on the keypad while the test is
being performed,
If the test fails, the message SEISMIC FAILis displayed. If thei or VIEW
key is pressed, a list of the failed zones is displayed which can be scrolled
through.
If the test succeeds, SEISMIC OK’ is displayed.
See also Seismic Sensor Testing [➙ 264].