Engineer programming via the browser
15
Configuring controller inputs & outputs
185
Siemens AB
A6V10276959
Security Products
18.11.2011
Output Type
System Output: Select the type from the dropdown menu. (See Output Types
and Output Ports [➙ 186])
Area Output: Only if (multiple) Areas is activated in menu Panel Settings >
System Settings > Options. Select an area and the type of system output for this
area. (See Output Types and Output Ports [➙ 186])
Zone Mapping: Select which zone should be mapped.
Mapping Gate: Select which mapping gate should be mapped.
Door Output: Select the door number and the type of system output for the door.
(See Output Types and Output Ports [➙ 186])
Keyswitch: Select the node ID for the required keyswitch and the required key
position to map to this output.
Description
Enter a text describing the output (max. 16 characters). This text will also appear on
the browser and keypad.
Output
Configuration
Mode: Select the operational mode. Continuous follows output type; Pulsed
toggles on and off when output type is active; Momentary generates a pulse
when output type activates.
Retrigger: Tick the box to retrigger momentary outputs.
On Time: Enter the On time that applies to momentary and pulsed outputs.
Off Time: Enter the Off time that applies to pulsed outputs.
Invert: Tick this box to invert the physical output.
Log: Tick this box to log the output state changes to the event log.
Calendar: Select if necessary the desired calendar. See page [➙ 236].