Appendix
21
Zone types
285
Siemens AB
A6V10276959
Security Products
18.11.2011
TECHNICAL
Intruder
The tech zone controls a dedicated tech zone output. When a tech zone
changes state, the tech zone output will follow. That is:
When the tech zone opens, tech zone o/p triggers on
When the tech zone closes, tech zone o/p goes off
If more than one tech zone has been assigned, the tech zone output will
remain on until all tech zones are closed.
MEDICAL
Hold-up
This zone type is used in conjunction with radio or hardwired medical
switches.
Activation in any mode will:
Trigger the medical digital communicator output (unless Local
attribute is set)
Cause the panel buzzer to sound (unless Silent attribute is set)
Display the message Medic Alarm
KEYARM
Intruder
This zone type is normally used in conjunction with a key lock
mechanism. A Keyarm zone will SET the System / Area / Common
Areas when it is OPENED and will UNSET the System/Area/Common
Areas when it is CLOSED.
If the zone with the keyarm zone type is assigned in an non area
system then the keyarm operation will SET/UNSET the system.
If the zone with the keyarm zone type is assigned to an area then
the keyarm operation will SET/UNSET the area.
If the zone with the keyarm zone type is assigned to a common area
then the keyarm operation will SET/UNSET all the areas in the
common area.
If the ‘Open only’ attribute is set then the armed status of the System
/ Area / Common Areas will toggle on each opening of the key lock. (
i.e. Open once to SET the system, Close and Open again to
UNSET)
If the ‘Fullset Enable’ attribute is set then zone activation will only
Fullset the system.
If the ‘Unset Enable’ attribute is set then zone activation will only
unset the system.
Keyarming will force set the system/area and auto-inhibit any open
zones or fault conditions.
Note: Your system will not comply with EN standards if you enable this
zone type to set the system without a valid PIN being required.
SHUNT
Intruder
This zone type is only available in Commercial Mode of operation.
Though the Shunt Alarm Zone type can be set in Domestic Mode of
operation, it has no effect.
This zone type when opened inhibits all zones that have the shunt
attribute set. This operation applies for both SET and UNSET modes. As
soon as the shunt zone is closed, the zones with the shunt attribute set
will become un-inhibited again.
X-SHUNT
Intruder
This zone type is only available in Commercial Mode of operation.
A zone programmed with the x-shunt zone type inhibits the next
consecutive zone on the system whenever it is opened. This operation
applies for both SET and UNSET modes. As soon as the x-shunt zone
type is closed the next zone becomes de-inhibited again.
DETECTOR FAULT
Fault
Detector Fault zones are 24 hour zones that are applicable to a detector
device, for example, a PIR. The fault zone type triggers the Fault output.
When the system is armed, a LED on the keypad and optional internal
audible alarm indicates the fault. Only the keypad LED is activated when
Unarmed.
This zone type will report the SIA messages, BT (Burglary Trouble) and
BTS (Burglary Trouble Restore) and for CID, a sensor trouble event
(380) is produced.