
Engineer programming via the browser
Configuring advanced settings
Keypad valid PIN – this condition can be configured for a particular user or for
any user. With this configuration, if the configured user (or any user) enters a
valid PIN, or presents a configured PACE, it will cause an instantaneous pulse
OFF/ON/OFF.
Keyswitch – the trigger can be configured for a specific key position on the
keyswitch.
Time Trigger –the trigger is on at the specific time entered in the box provided,
in the format hh:mm.
Your system will not comply with EN standards if you enable a trigger to set the
system without a valid PIN being required.
15.13.3 Mapping Gates
Triggers are used with Mapping Gates, which are virtual outputs defined by the
user that can be mapped to a physical output. There can be a maximum of 256
Mapping Gates.
For continuous output, when the trigger is a valid user code, both states must be
the same, either both negative or both positive.
Select Settings > Advanced > Mapping Gates.
The following window will be displayed.
1. Enter a Description for the gate. This is important as no mapping gate number,
only the description, is displayed on the Outputs user page for turning on and
2. Tick the Protected check box if you do not want to allow users to turn on and
off this gate, even if they have the right to do so. A protected gate does not
appear in the Outputs setting page for users.
3. Select desired Quick Key.
A quick key is a ‘#’ followed by a single digit pressed at the keypad. If a
shortcut is configured and is pressed at the keypad, the user is prompted to
turn the output on or off.
Comentarios a estos manuales