Siemens SPCK421 Especificaciones Pagina 157

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 296
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 156
Engineer programming via the browser
15
Changing system settings
157
Siemens AB
A6V10276959
Security Products
18.11.2011
!
Engineer Restore
(Impact only if Region "UK" is chosen): If this option is
enabled, then the engineer has to restore the confirmed
alarms. This option works together with the function
"Confirmation".
!
Coded Restore
Grade 3 only: A user, who does not have the right to restore
an alarm, is able to restore the alarm with this feature. On
resetting an alarm, a 6 digit code is required. The user must
call the installer to generate a restore code, with which the
user is able to restore the alarm.
Offline Tamper
Enable this for offline expander zones to generate a zone
tamper.
Reset Cards
If enabled, access cards passback state will be reset every
day at midnight.
Duress
Select one of the following Duress codes to activate this
function. Code +1 or Code + 2.
!
Antimask Set
Select the type of event reported resulting from antimask
detection when panel is Set. Options are Disabled, Tamper,
Trouble or Alarm.
The option can only be configured when the panel is in
‘Unrestricted’ mode. In Grade 2 or 3 mode, the type of event
reported is in accordance with the standards for the selected
region:
Ireland - Alarm
All other regions - Alarm
!
Antimask Unset
Select the type of event reported resulting from antimask
detection when panel is Unset. Options are Disabled,
Tamper, Trouble or Alarm.
The option can only be configured when the panel is in
‘Unrestricted’ mode. In Grade 2 or 3 mode, the type of event
reported is in accordance with the standards for the selected
region:
Ireland - Disabled
All other regions - Tamper
Suspician Audible
If enabled then WPA Suspicion alerts have audible and
visible indicators on the keypad.
Pro
End Of Line
(EOL RESISTANCE)
Select the End Of Line termination resistors that will apply to
either All zones on the system or New zones added to the
system. Tick the Checkbox to enable the appropriate
feature.
Show Offline Cameras
If enabled, offline cameras will be displayed on the keypad
in Unset mode.
Seismic Test on Manual
Set
If enabled, all seismic sensors in any area that is being set
will be tested before area or system set.
!
Confirmation
The Confirmation variable determines when an alarm is
deemed to be a confirmed alarm.
Garda:
This will enforce the policies for confirmed alarms
required by the Irish Garda. The requirement stipulates
that an alarm will be deemed to be a confirmed alarm
as soon as a second zone alarm is activated on the
system within the one alarm set period. The Garda
confirmation option is automatically set whenever the
Standards -> Region option is set to Ireland.
DD243:
This will enforce compliance with the UK Police
Vista de pagina 156
1 2 ... 152 153 154 155 156 157 158 159 160 161 162 ... 295 296

Comentarios a estos manuales

Sin comentarios