Engineer programming via the browser
15
Configuring zones, doors and areas
171
Siemens AB
A6V10276959
Security Products
18.11.2011
The following parameters (with the exception of the Interlock parameter) are only
relevant in the following cases:
A Calendar is selected (see Schedule [➙ 170]), or
Unset Duration is enabled (has a value greater than zero), or
Both of the above conditions are met.
Auto Set Warning
Enter the number of minutes to display a
warning before Auto Setting. ( 0 - 30 )
Note that the panel sets either at the
scheduled time or at the time defined by the
Delay Unset parameter. The first warning is
displayed at the configured time before the
scheduled time. There are further warnings
starting at one minute before setting time.
Auto Set Cancel
Enables the user to cancel Auto Setting by
entering a code in the keypad.
Auto Set Delay
Enables a user to delay Auto Setting by
entering a code in the keypad.
Keyswitch
Enables Auto Setting to be delayed using
Keyswitch Expander.
Delay Interval
Enter the number of minutes by which to
delay Auto Set. (1 - 300 )
Delay Counter
Enter the number of times that Auto Setting
can be delayed. (0 – 99: 0 = unlimited)
Delay Unset
Enter the number of minutes by which to
delay an Unset. (0 = no delay)
Interlock Group
Select an Interlock Group to assign to this
area. Interlocking only allows one area
within the group to be Unset at any time.
Typically used in ATM areas.
Unset Duration
If area is Unset for longer than this it will Set
automatically. (Range 0 – 120 mins: 0 = not
active).
Dual PIN
If this option is enabled, two PINs are
required to Set or Unset the area with the
keypad. Both PINs must belong to users
who have the required user right for the
operation (Setting or Unsetting).
If the second PIN is not entered within 30
seconds, or it is wrong, then the area cannot
be Set or Unset.
Late Working Support
An example of using the setting and unsetting parameters is for late working
situations where a calendar has been configured for automatic setting of a
premises at a particular time but staff may need to work late on occasion and the
automatic setting needs to be delayed.