more details, see Engineering PINs [➙ 68].
12.1 Engineer modes
The SPC system works under 2 programming modes for authorised installation
engineers: Full and Soft. In the browser, log off is only permitted in Soft Engineer
mode.
Full Engineer Mode
All alerts, faults and tampers must first be isolated or cleared before exit from the
Full Engineer mode is allowed.
Full Engineer mode provides extensive programming functionality. However,
programming in Full Engineer mode disables all alarm settings, reports and output
programming for the system. For full review of Full Engineer menu options, refer to
page [➙ 75].
[Soft] Engineer mode
Soft Engineer mode provides fewer programming functions and does not affect any
outputs programmed in the system. For full review of [Soft] Engineer menu options,
refer to page [➙ 74].
12.1.1 Engineer PINs
The start up Engineer default programming PIN is ‘1111’.
If an installation is changed from Grade 2 to Grade 3 at any time after start-up, all
PINs are prefixed with a 0. Therefore, the default Engineer PIN will be ‘01111’.
Increasing the number of digits for the PIN (see System Options [➙ 154]) will add
the relevant number of zeros to the front of an existing PIN (for example, 001111
for a 6 digit PIN)
12.2 Programming tools
Keypad
The keypad is quick onsite navigation of menus and programming. The authorised
installation engineer must set initial default configurations using the keypad.
Programming of proximity card/device reader and assignment to users also must
be done using the keypad.