Unrestricted Grade
A Security Grade setting of Unrestricted does not apply any regionally approved
security restrictions to the installation. Instead, the Unrestricted setting enables an
engineer to customize the installation by changing security policy options and
configuring additional options which do not comply with the selected regional
security compliance.
Unrestricted configuration options are denoted in this document by the following
symbol:
See System Options for details of configuring system policies.
15.7.2.1 Installation type
The installation type determines the type of zones that can be programmed on the
panel and the features that will be presented.
You can choose between the following installation types:
Domestic: Suitable for residential installations with one or more areas and a
small-to-moderate number of alarm zones. Appropriate Input and Output
functions are available for the system configuration.
Commercial: Suitable for business installations with multiple areas and a large
number of alarm zones. Extended Input and Output functions such as calendar
and autosetting are available.
Financial: Suitable for banks and other financial institutions with vault and ATM
environments.
15.7.2.2 Region
The region setting of the system sets the market specific security requirements for
the installation in accordance with the Grades.
15.7.2.3 Grade
EN 50131 Grade 2: The Grade is defined according the EN Standard in terms
of User/Engineer and System rights. For example, an engineer code is required
to restore a tamper alarm.