- AUTO: is not recommended, only with the exception of very small
installations.
7. Choose the installation topology: LOOP (Ring) or SPUR (Chain).
The system scans for the quantity of keypads, expanders, door controllers
and available zone inputs.
8. Press NEXT for scanning all the X-BUS devices.
PROGRAMMING MODE will be displayed.
The Start-up setting is complete.
1. Check the alerts in the menu SYSTEM STATUS > ALERTS. Otherwise you will
not be allowed to exit the Engineer Mode.
2. Configure the system by keypad, SPC Pro or web browser.
See also
Domestic, Commercial and Financial mode default settings
[➙ 272]
12.4 Creating system users
By default the SPC system only allows engineer access on the system. The
engineer must create a user profile to allow on-site users to set, unset, and perform
basic operations on the system as required. The system allows all user PINs within
the code range i.e. if a 4 digit code is used then all user PINs between 0000 and
9999 would be permissible.
Only a MANAGER type user has the ability to grant manufacturer access to the
system (i.e. allow a firmware upgrade of the panel). If a user is typically going to
be upgrading firmware remotely, create a MANAGER type user for that purpose.
To create a user:
1. Enter the Engineer Programming PIN (Default PIN is 1111. See Engineering
3. Press SELECT.
The option to ADD a user is displayed.
4. Press SELECT.
The system generates and displays next available user name.
5. Press SELECT to use the default name and numbers displayed, or use the
keypad to enter a customized user name.
6. Press SELECT.
There are 3 types of users available: STANDARD USER, MANAGER, or
LIMITED USER.
7. Scroll to the preferred user type and press SELECT.
The system generates a default code for the new user.