Siemens SPCK421 Especificaciones Pagina 220

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 296
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 219
15
Engineer programming via the browser
Configuring communications
220
Siemens AB
A6V10276959
Security Products
18.11.2011
For commands using code, the format of the text is the code followed by either a
space or a full stop. Where **** is the code and “commandis the command:
****.command or **** command.
For example, the command HELP is this text: **** HELP or ****.HELP
COMMANDS (**** = code)
Using Code
Using
Caller ID
Action
Response
**** HELP
****.HELP
HELP
All available commands displayed
All available
commands
**** FSET
****.FSET
FSET
Fullset Alarm
Time/date of system
set. If applicable,
responds with open
zones/forceset
zones
**** USET
****.USET
USET
Unset Alarm
System Unset
**** SSTA
****.SSTA
SSTA
Status displayed
Status of system and
applicable areas
**** XA1.ON
****.XA1.ON
Where X10 device is identified as “A1”, it is
triggered on.
Status of “A1”
**** XA1.OFF
****.XA1.OFF
Where X10 device is identified as “A1”, it is
triggered off.
Status of “A1”
**** LOG
****.LOG
Up to 10 recent events displayed
Recent events
**** ENGA.ON
****.ENGA.ON
ENG.ON
Enable Engineer access
Engineer status
**** ENGA.OFF
****.ENGA.OFF
ENG.OFF
Disable Engineer access
Engineer status
**** MANA.ON
****.MANA.ON
Enable Manufacturer access
Manufacturer status
**** MANA.OFF
****.MANA.OFF
Disable Manufacturer access
Manufacturer status
**** O5.ON
****.O5.ON
Where mapping gate is identified as “O5”, it
is triggered on
Status of “O5”
**** O5.OFF
****.O5.OFF
Where mapping gate is identified as “O5”, it
is triggered off
Status of “O5”
****.ASET
Allows Partset A of alarm by SMS
****.BSET
Allows Partset B of alarm by SMS
****.CLR
Allows clear alerts by SMS
Vista de pagina 219