21 Appendix
21.1 Network cable connections
A PC can be connected directly to the Ethernet interface of the SPC controller or
via a LAN connection. The tables below show the 2 possible connection
configurations.
If the SPC is connected to an existing network via a hub, then connect a
straight through cable from the hub to the SPC and another from the hub to the
PC.
If the controller is not connected to a network (i.e. a hub or switch is not used),
then a crossover cable should be connected between the SPC controller and
the PC.
Use the straight through cable for connecting the SPC controller to a PC via a hub.
RJ45 PIN
RJ45 PIN
1 (RX +)
1 (TX +)
2 (RX -)
2 (TX -)
3 (TX+)
3 (RX+)
6 (TX-)
6 (RX-)
Use the crossover cable for connecting the SPC controller directly to a PC.
RJ45 PIN
RJ45 PIN
1 (RX +)
3 (TX+)
2 (RX -)
6 (TX-)
3 (TX+)
1 (RX +)
6 (TX-)
2 (RX -)
21.2 Controller status LEDs
LED
Function
LED 1
Wireless Data
FLASHING: wireless data is being received by the wireless module
OFF: no wireless data is being received