Engineer programming via the browser
15
Ethernet interface
117
Siemens AB
A6V10276959
Security Products
18.11.2011
Connect
1
JP9
2
Ethernet port
3
To Ethernet port on PC
If the SPC Ethernet interface is connected to an existing Local Area Network
(LAN), please consult the network administrator for that LAN before connecting to
the panel. Default IP Address: 192.168.1.100
Connect the cable
Connect an Ethernet cable from the Ethernet interface on the PC to the
Ethernet port on the controller board
OR
If connecting directly from a PC then a cross over-cable must be used. See
page [268].
The LEDs to the right of the Ethernet interface indicate a successful data
connection (Right LED on) and Ethernet data traffic (Left LED flashing).
Determine the IP address of the SPC controller
1. Entering the Engineer mode (See Engineering PINs [➙ 68]).
2. Using the up/down arrow keys, scroll down COMMUNICATION option and
press SELECT.
3. Scroll to ETHERNET PORT and press SELECT.
4. Scroll to IP ADDRESS and press SELECT.