Clear alarm with NC START or RESET key and continue the program.
10781 Channel %1 block %2 illegal orientation of involute with tool radius
compensation
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Tool radius compensation is possible for involutes only if the compensation plane matches the invo-
lute plane.
Reaction: Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy: Modify part program.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
10782 Channel %1 block %2 illegal curve type with tool radius compensation
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: This alarm occurs, if an attempt is made to apply the tool radius compensation to a curve type for
which this function is not implemented. The only cause at present: Involute with 3D tool radius com-
pensation.
Reaction: Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy: Modify part program.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
10783 Channel %1 block %2 tool radius compensation type requires orientation
transformation
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: This alarm occurs, if an attempt is made to activate a tool radius compensation which must enable a
tool orientation change and the _Orientation transformation_ option is not available. This alarm can
only occur if one of the following G code is active in the G code group 22:
- CUT3DC
- CUT3DCC
- CUT3DCCD
Reaction: Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy: - Modify part program
- Install "Orientation transformation" option
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.