NCK alarms/ISO alarms
06/2007 Overview of alarms
2-105
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
12556 Channel %1 block %2 name %3 Name is already known
Parameters: %1 = Channel number
%2 = Block number, label
%3 = Source symbol
Definitions: The name of the symbol to be created belongs to the scope of the NC language and thus already
known. Although the NC function is not active, this name can no longer be used for GUDs, macros
and PROC definitions.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Press the NC Stop key and select the function "Correction block" with the softkey PROGRAM COR-
RECT. The correction pointer positions on the incorrect block.
Correct the name used (typing error).
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
12560 Channel %1 block %2 programmed value %3 exceeds allowed limits
Parameters: %1 = Channel number
%2 = Block number, label
%3 = Source string
Definitions: In a value assignment, the permissible value range of the data type has been exceeded.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Press the NC Stop key and select the function "Correction block" with the softkey PROGRAM COR-
RECT. The correction pointer positions on the incorrect block.
Assign value within the value range of the various data types, or if necessary use another type in order
to increase the size of the value range.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
12570 Channel %1 block %2 too many motion synchronous actions in %3
Parameters: %1 = Channel number
%2 = Block number, label
%3 = Source symbol
Definitions: No more than 16 actions are allowed in a block with motion synchronous action.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Reduce the number of programmed actions.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
12571 Channel %1 block %2 %3 not permissible for motion synchronous action
Parameters: %1 = Channel number
%2 = Block number, label
%3 = Source symbol
Definitions: The predefined subprogram %3 specified here is not allowed in a block with motion synchronous
action. It may only be contained in a "normal" block.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Modify program.