Siemens SINUMERIK 802D sl Especificaciones Pagina 286

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 392
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 285
Overview of alarms 06/2007
Cycle alarms
2-286
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007 Edition
61193 Channel %1 block %2: compressor option not set up
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The alarm is triggerd by the following cycles: CYCLE832.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: --
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61194 Channel %1 block %2: spline interpolation option not set up
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The alarm is triggerd by the following cycles: CYCLE832.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: --
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61197 Channel %1 block %2: no swiveling in JOG --> active WO G%4 and basic
frames contain rotations
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Alarm triggered by following cycles: CYCLE800.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: --
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61198 Channel %1 block %2: no swiveling in JOG --> several active basic
frames(G500) contain rotations
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Alarm triggered by following cycles: CYCLE800.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: --
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61199 Channel %1 block %2: approach of tool and swivel data record change
(TOOLCARRIER) not allowed
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Alarm triggered by following cycles: CYCLE800.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.