NCK alarms/ISO alarms
06/2007 Overview of alarms
2-245
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
Remedy: Check active speed limitation.
Configure a lower zero mark search velocity MD 34040 REFP_VELO_SEARCH_MARKER. Check
tolerance range for the actual velocity in MD 35150 SPIND_DES_VELO_TOL. Set a different refer-
encing mode MD 34200 ENC_REFP_MODE=7
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
22064 Channel %1 axis %2 reference point approach: zero marker search
velocity (MD) is too high
Parameters: %1 = channel number
%2 = axis name, spindle number
Definitions: The configured zero mark search velocity is too high. The encoder limit frequency is exceeded for the
active measuring system.
Reaction: NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Configure a lower zero mark search velocity MD 34040 REFP_VELO_SEARCH_MARKER. Check
encoder limit frequency configured in MD 36300 ENC_FREQ_LIMIT and MD 36302
ENC_FREQ_LIMIT_LOW. Set a different referencing mode
MD 34200 ENC_REFP_MODE=7.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
22100 Channel %1 block %3 spindle %2 chuck speed exceeded
Parameters: %1 = channel number
%2 = axis name, spindle number
%3 = block number, label
Definitions: The actual speed of the displayed spindle is greater than the value entered in the axis-specific
machine data 35100 SPIND_VELO_LIMIT plus the tolerance value specified in machine data 35150
SPIND_DES_VELO_TOL.
If the drive actuator has been optimized properly, the alarm cannot occur!
Reaction: Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Channel not ready.
Remedy: Check and correct the start-up and optimization data of the drive actuator in accordance with the
Installation and Start-up Guide.
Increase the tolerance window in machine data 35150 SPIND_DES_VELO_TOL.
Program Con-
tinuation:
Teileprogramm neu starten.Clear alarm with the RESET key in all channels of this mode group.
Restart part program.
22101 Channel %1 block %3 spindle %2 maximum speed for encoder
resynchronization exceeded
Parameters: %1 = channel number
%2 = axis name, spindle number
%3 = block number, label
Definitions: The limit frequency of the active encoder (axis-specific MD 36300 ENC_FREQ_LIMIT[0]) has been
exceeded with function G33 (thread cutting with encoder), G95 (revolutional feedrate) or G96 (con-
stant cutting rate). As a result, the spindle is no longer synchronized.
Reaction: NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Comentarios a estos manuales