Overview of alarms 06/2007
NCK alarms/ISO alarms
2-116
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
Remedy: Modify the machining program so that the nesting depth is reduced, e.g. using the editor copy a sub-
routine of the next nesting level into the calling program and remove the call for this subroutine. This
reduces the nesting depth by one program level.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
14013 Channel %1 block %2 number of subroutine passes invalid
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: In a subroutine call the programmed number of passes P is zero or negative.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Program number of passes between 1 and 9 999.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
14014 Channel %1 selected program %3 not available or will be edited
Parameters: %1 = channel number
Definitions: The selected part program is not contained in the NC memory.
Reaction: Alarm display.
Remedy: Reload the program in the NC memory or check and correct the name of the directory (workpiece
overview) and the program (program overview).
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
14015 Channel %1 block %2 program %3 is not enabled
Parameters: %1 = channel number
Definitions: The user does not have any execution rights for the file.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Change the user rights
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
14016 Channel %1 block %2 error when calling the subroutine via M/T function
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The following conflict was detected in a subroutine call per M or T function: In the block referenced
with parameter %2
– an M or T function replacement has already been activated
– a modal subroutine call is already active
– a subroutine return has been programmed
– an M98 subroutine call is active (only in external language mode)
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: An M or T function replacement is only possible if a subprogram call or return jump has not already
been performed as a result of a subprogram call or return.
The part program must be corrected accordingly.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.