Siemens SINUMERIK 802D sl Especificaciones Pagina 340

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 392
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 339
Overview of alarms 06/2007
SINAMICS-Parameters
2-340
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007 Edition
400015 PROFIBUS DP: I/O defect: log adr. [x] bus adr./slot: [y/z]
Definitions: The PLC-AWP is using peripheral addresses which are not available.
[x]Logical I/O address
[y]Bus address (slave)
[z]Slot number
Error causes:
PROFIBUS peripheral has no voltage
Slave bus address set incorrectly
PROFIBUS connection faulty
Active MD 11240 (SDB PROFIBUS configuration) is set incorrectly
Reaction: PLC Stop
Remedy: Rectify the error using the error cause
Program Con-
tinuation:
Switch control OFF - ON.
2.5 SINAMICS-Parameters
A detailed description of the SINAMICS parameters is provided in the following
publication:
LH1, SINAMICS_S Parameter Manual
Vista de pagina 339
1 2 ... 335 336 337 338 339 340 341 342 343 344 345 ... 391 392

Comentarios a estos manuales

Sin comentarios