Cycle alarms
06/2007 Overview of alarms
2-305
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007 Edition
61286 Channel %1 block %2: machining not possible, check tool angle.
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Machining not possible with the specified tool.
Alarm triggered by following cycles: F_UCUT_T.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Use a suitable tool.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61287 Channel %1 block %2: no master spindle active.
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: No master spindle active.
Alarm triggered by following cycle: F_TFS.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Activate the master spindle (machine data 20090).
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61300 Channel %1 Block %2: Probe defective
Parameters: %1 = Channel number
%2 = Block number, label
Definitions:
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61304 Channel %1 Block %2: Allowance
Parameters: %1 = Channel number
%2 = Block number, label
Definitions:
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61305 Channel %1 Block %2: Dimension too small
Parameters: %1 = Channel number
%2 = Block number, label
Definitions:
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: