NCK alarms/ISO alarms
06/2007 Overview of alarms
2-43
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
6412 TO unit %1 tool %2 has reached its monitoring limit with D = %4
Parameters: %1 = TO unit
%2 = Tool identifier (name)
%3 = Duplo number
%4 = D number
Definitions: Tool monitoring:
This message informs that the specified D offset has reached its monitoring limit for a time- or quantity-
monitored tool.
If possible, the D number is displayed; if not, value 0 is assigned to the 4th parameter.
The actual type of tool monitoring is a tool property (see $TC TP9).
If replacement tools are not being used, the duplo number specified has no meaning.
The alarm is triggered through the MMC or PLC (=OPI interface). The channel context is not defined.
The TO unit is specified for this reason.
Reaction: Interface signals are set.
Alarm display.
Remedy: For information only. The user must decide what to do.
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
6413 Channel %1 tool %2 has reached its monitoring limit with D = %4
Parameters: %1 = TO unit
%2 = Tool identifier (name)
%3 = Duplo number
%4 = D number
Definitions: Tool monitoring:
This message informs that the specified D offset has reached its monitoring limit for a time- or quantity-
monitored tool.
If possible, the D number is displayed; if not, value 0 is assigned to the 4th parameter.
The actual type of tool monitoring is a tool property (see $TC TP9).
If replacement tools are not being used, the duplo number specified has no meaning.
The alarm originates during NC program execution.
Reaction: Interface signals are set.
Alarm display.
Remedy: For information only. The user must decide what to do.
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
6415 TO unit %1 tool %2 with tool edge no. %3 has reached tool monitor
warning limit
Parameters: %1 = TO unit
%2 = Tool identifier
%3 = Cutting edge number
Definitions: This message informs that at least one cutting edge of the time or quantity monitored tool has reached
its monitoring limit. The alarm was triggered through the OPI interface (MMC, PLC). The channel con-
text is not defined. The TO unit was specified for this reason.
Reaction: Interface signals are set.
Alarm display.
Remedy: For information only. The user must decide what to do.
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
6416 Channel %1 tool %2 with tool edge no. %3 has reached tool monitor
warning limit
Parameters: %1 = Channel number
%2 = Tool identifier
%3 = Cutting edge number