NCK alarms/ISO alarms
06/2007 Overview of alarms
2-205
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
17200 Channel %1 block %2 deleting tool data not possible
Parameters: %1 = channel number
%2 = block number, label
Definitions: An attempt has been made to delete from the part program the tool data for a tool currently involved
in a machining operation. Tool data for tools involved in the current machining operation may not be
deleted.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Deselect tool
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
17210 Channel %1 block %2 access to variable not possible
Parameters: %1 = channel number
%2 = block number, label
Definitions: The variable cannot be written/read directly from the part program.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Modify part program.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
17224 Channel %1 block %2 tool T/D= %3 - tool type %4 is not permitted
Parameters: %1 = Channel number
%2 = Block number, label
%3 = Incorrect T no. / D no.
%4 = Incorrect tool type
Definitions: On this system, it is not possible to select tool offsets of the
indicated tool types.
The variety of tool types can both be limited by the machine OEM
and be reduced on individual control models.
Only use tools of the tool types permitted for this system.
Check whether an error has occurred on defining the tool.
Reaction: Correction block is reorganized.
Interpreter stop
Interface signals are set.
Alarm display.
Remedy: Correct the NC program or correct the tool data
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
17270 Channel %1 block %2 call-by-reference: illegal variable
Parameters: %1 = channel number
%2 = block number, label
Definitions: Machine data and system variables must not be transferred as call-by-reference parameters.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Correct the NC program: Assign the value of the machine data or system variable to a program-local
variable and transfer this as parameter.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.