Overview of alarms 06/2007
NCK alarms/ISO alarms
2-114
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
Definitions: When calling a modal macro no other modal macro, modal cycle or modal subroutine may be active.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Change part program
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
14000 Channel %1 block %2 illegal end of file
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: An M02 or an M30 for main programs, an M17 for subroutines, is expected as end of file.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Check whether the program end has been omitted or whether in the last program block a jump has
been made to a program section that contains the end identification.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
14001 Channel %1 block %2 illegal end of block
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: After system-internal data manipulation (e.g. when transferring blocks from an external source) a sub-
file can end without having LF as the last character.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Read out the part program, modify it with a text editor (e.g., insert blanks or comments before the dis-
played block), so that after reading it in again the part program has a different structure in the memory.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
14005 Channel %1 block %2 program %3 program-specific start disable has
been set
Parameters: %1 = Channel number
%2 = Block number, label
%3 = Program name
Definitions: Program %3 cannot be executed, as the program-specific start disable has been set for this file.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Reset the program-specific start disable for file %3.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
14008 Channel %1 block %2 WRITE command writes in the temporary memory
area in /_N_EXT_DIR
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: A workpiece is executed from an external data register (Execute from external drives function). The
part programs are temporarily stored in the NCK directory /_N_EXT_DIR. An attempt is now made to
write in this temporary directory with a WRITE command.
The alarm is intended to indicate that this data is not stored in the original directory on the external
data carrier, and will be lost at the next part program selection because the programs in the directory
/_N_EXT_DIR will then be deleted.
Reaction: Alarm display.
Vista de pagina 113
1 2 ... 109 110 111 112 113 114 115 116 117 118 119 ... 391 392

Comentarios a estos manuales