Overview of alarms 06/2007
NCK alarms/ISO alarms
2-50
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
8000 Channel %1 option 'user interrupt programs' not set
Parameters: %1 = channel number
Definitions: The signals of NCK inputs are required in order to activate the interrupt routines and rapid lift from
contour. This function is not included.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Do not use fast interrupt inputs!
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
8010 Option 'activation of more than %1 axes' not set
Parameters: %1 = number of axes
Definitions: More machine axes have been defined through MD 20070 AXCONF_MACHAX_USED than are
allowed in the system.
Reaction: NC not ready.
Mode group not ready, also effective for single axes
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Please inform the authorized personnel/service department. The sum of all axes that have been con-
figured through the channel-specific MD 20070 AXCONF_MACHAX_USED, must not exceed the
maximum number of axes.
Program Con-
tinuation:
Switch control OFF - ON.
8020 Option 'activation of more than %1 channels' not set
Parameters: %1 = Number of channels
Definitions: A 2nd channel has been indicated but the corresponding option does not exist.
Reaction: NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: In the system-specific MD 10010 ASSIGN_CHAN_TO_MODE_GROUP, reduce the number of chan-
nels to 1 or retrofit the option for a 2nd channel.
Program Con-
tinuation:
Switch control OFF - ON.
8021 Option 'activation of more than %1 mode groups' not set
Parameters: %1 = Number of mode groups
Definitions: The option for the number of mode groups is not compatible with the activated mode group.
Reaction: NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Add option for more mode groups. Activate fewer mode groups.
Program Con-
tinuation:
Switch control OFF - ON.
8022 Option 'activation of more than %1KB SRAM' not set
Parameters: %1 = Memory size
Definitions: The option for memory extension does not correspond to the active SRAM.
Reaction: NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Please inform the authorized personnel/service department.
- Buy option
- Activate less SRAM
Vista de pagina 49