Siemens SINUMERIK 802D sl Especificaciones Pagina 354

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 392
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 353
List of action numbers 06/2007
3-354
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007 Edition
No. 69, PROGESTON
No. 70, PROGESTOFF
No. 71, STOPATIPOBUFFER_ISEMPTY_ALARM
No. 72, STOPATIPOBUF_EMPTY_ALARM_REORG
No. 73, CONDITIONAL_STOPATEND
Explanation Activate program test (VDI signal: Program test).
Cause 1. Tool management is active
2. The NCK channel is in a state other than "ready"
Remedy Backing up tool data
Abort the program or process with the Reset key or
wait for end of program
Explanation Deactivate program test (VDI signal: Program test).
Cause The NCK channel is in a state other than "ready"
Remedy Abort the program or process with the Reset key or
wait for end of program
Explanation Stop at the end of block preparation (alarm)
Cause -
Remedy -
Explanation Stop at the end of block preparation with subsequent reorganization of block processing
(alarm)
Cause Nesting depth too great
Remedy Wait until the preceding ASUB is complete or
Abort program
Explanation Conditional stop at block end. If, after continuation by means of an NC Start, there is still
a reason to stop "Stop at block end", the program stops again.
Cause -
Remedy -