Overview of alarms 06/2007
NCK alarms/ISO alarms
2-220
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
2. The axis is stationary at the last indexing position. In incremental traversing, the working area limi-
tation or the software limit switch is reached without an indexing position being located in front of it at
which a stop could be made.
Reaction: Alarm display.
Remedy: Please inform the authorized personnel/service department. Correct (add to) the list of indexing posi-
tions by means of the machine data
MD 10900: INDEX_AX_LENGTH_POS_TAB_1
MD 10910: INDEX_AX_POS_TAB_1
MD 10920: INDEX_AX_LENGTH_POS_TAB_2
MD 10930: INDEX_AX_POS_TAB_2
or set the working area limits or the software limit switches to other values.
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
20055 Channel %1 master spindle not present in JOG mode
Parameters: %1 = channel number
Definitions: The displayed axis is to be traversed as machine axis in JOG mode with revolutional feed, but no mas-
ter spindle has been defined from which the actual speed could be derived.
Reaction: Local alarm reaction.
Interface signals are set.
Alarm display.
Remedy: Please inform the authorized personnel/service department.
If the revolutional feed is also to be active in JOG mode, then a master spindle must be declared via
the channel-specific machine data 20090 SPIND_DEF_MASTER_SPIND. In this case you have to
open a screen in the PARAMETER operating area with the softkeys "SETTINGDATA" and "JOG
DATA" and preselect the G function G95 there. The JOG feedrate can then be entered in [mm/rev].
(If 0 mm/rev is set as JOG feed, the control takes the value assigned in the axis-specific MD 32050
JOG_REV_VELO or in the case of rapid traverse overlay 32040 JOG_REV_VELO_RAPID).
The revolutional feed in JOG mode is deactivated by changing the G function from G95 to G94.
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
20056 Channel %1 axis %2 no revolutional feedrate possible. Axis/spindle %3
stationary
Parameters: %1 = channel number
%2 = axis name, spindle number
%3 = axis name, spindle number
Definitions: An axis is to travel in JOG with revolutional feed, but the feed of the spindle/axis from which the feed
is to be derived is 0.
Reaction: Alarm display.
Remedy: Traverse the spindle/axis from which the feed is to be derived.
Program Con-
tinuation:
Alarm display showing cause of alarm disappears. No further operator action necessary.
20057 Channel %1 block %2 revolutional feedrate for axis/spindle %3 is <= zero
Parameters: %1 = channel number
%2 = block number, label
%3 = axis name, spindle number
Definitions: Revolutional feed has been programmed for an axis/spindle, but the velocity was not programmed or
the programmed value is smaller than or equal to zero.
Reaction: Correction block is reorganized.
Local alarm reaction.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Please inform the authorized personnel/service department.
Correct part program.