Vista de pagina 112
NCK alarms/ISO alarms
06/2007 Overview of alarms
2-113
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
Definitions: When programming G07.1 (cylinder interpolation TRACYL), no cylinder radius has been pro-
grammed. Selection of the cylinder interpolation (TRACYL) with G07.1 C <cylinder radius> deselect
with G07.1 C0. For "C" the name of the rotary axis defined in the TRACYL machine data has to be
programmed.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: G07.1 block, program the cylinder radius under the name of the rotary axis for the cylinder interpola-
tion.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
12726 Channel %1 block %2 illegal plane selection with parallel axes
Parameters: %1 = channel number
%2 = block number, label
Definitions: In a block with plane selection (G17 – G19), a basic axis of the coordinate system must not be pro-
grammed together with the parallel axis assigned
to it.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: For plane selection with G17, G18, G19 either program the basic axis of the coordinate system or the
assigned parallel axis.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
12728 Channel %1 block %2 distance for double turret not set
Parameters: %1 = channel number
%2 = block number, label
Definitions: The tool clearance for the double turret head in the setting data 42162
EXTERN_DOUBLE_TURRET_DIST is 0.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Enter tool clearance for the double turret head in the setting data 42162
EXTERN_DOUBLE_TURRET_DIST.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
12730 Channel %1 block %2 no valid transformation machine data
parameterized
Parameters: %1 = channel number
%2 = block number, label
Definitions: The machine data 24100 TRAFO_TYPE_1, 24110 TRAFO_AXES_IN_1[1],
24210 TRAFO_AXES_IN_2[1] are incorrectly set for G07.1, G12.1.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Enter valid transformation identifier for TRACYL in MD 24100 TRAFO_TYPE_1 and the rotary axis
number in MD 24110 TRAFO_AXES_IN_1[1] or MD 24210 TRAFO_AXES_IN_2[1].
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
12740 Channel %1 block %2 modal macro call %3 not possible
Parameters: %1 = channel number
%2 = block number, label
%3 = source string