Siemens SINUMERIK 802D sl Especificaciones Pagina 201

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 392
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 200
NCK alarms/ISO alarms
06/2007 Overview of alarms
2-201
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
Definitions: An attempt was made to read or set a digital NCK output via the system variable $A_OUT [n] with the
index [n] greater than the specified upper limit in the NCK machine data 10360
FASTIO_DIG_NUM_OUTPUTS.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Program index [n] of the system variable $A_OUT [n] only between 0 and the value in the NCK
machine data 10350 FASTIO_DIG_NUM_OUTPUTS.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
17120 Channel %1 block %2 analog input no. %3 not activated
Parameters: %1 = channel number
%2 = block number, label
%3 = no. of input
Definitions: An attempt has been made by means of the system variable $A_INA[n] to read an analog input n that
has not been activated by the MD 10300 FASTIO_ANA_NUM_INPUTS.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Please inform the authorized personnel/service department. Modify part program or machine data
accordingly.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
17130 Channel %1 block %2 analog output no. %3 not activated
Parameters: %1 = channel number
%2 = block number, label
%3 = no. of output
Definitions: An attempt has been made by means of the system variable $A_OUTA[n] to write or read an analog
output n that has not been activated by the MD 10310 FASTIO_ANA_NUM_OUTPUTS.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Please inform the authorized personnel/service department. Modify part program or machine data
accordingly.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
17140 Channel %1 block %2 NCK output %3 is assigned to a function via
machine data
Parameters: %1 = channel number
%2 = block number, label
%3 = no. of output
Definitions: The programmed digital/analog output is assigned to an NC function (e.g. software cams).
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Please inform the authorized personnel/service department. Use another output or deactivate concur-
rent NC function via MD.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
17150 Channel %1 block %2 maximum of %3 NCK outputs programmable in the
block
Parameters: %1 = channel number
%2 = block number, label
%3 = number
Vista de pagina 200