This attribute applies only to supported storage CLIMs (G5 and later), and
indicates whether or not – at the time of discovery – the CLIM had been
Registered with Key Managers
successfully registered to the Key Manager or Key Manager Cluster using
the Register CLIMs with Key Managers guided procedure.
The version of storage software running on the CLIM.Storage Software Version
Indicates whether or not the CLIM has exceeded its temperature threshold
for proper operation. The possible values are “Temperature sensing not
Temperature Status
supported by this system,“ “Normal”, “Degraded,” and “Critical.” If the
value is not available, this attribute is not displayed.
List of physical Ethernet interfaces on the CLIM that are operational.Up Physical Network Interfaces
The connectivity status of the CLIM to the ServerNet X fabric. Displayed for
both X1 and X2 fabrics, provided the CLIM is configured for two connections
per ServerNet fabric. Possible values include:
X1 Fabric Connection State
X2 Fabric Connection State
Correctly Connected: The CLIM is correctly connected to the ServerNet X
fabric.
Not Connected: The CLIM is not connected to the ServerNet X fabric.
Location Mismatch: The CLIM is configured to be connected to a p-switch,
but is connected to a different port.
System Name Mismatch: The CLIM is configured with a system name that
does not match the name of the system to which it is connected.
Operation Mode Mismatch: The operation mode does not match with the
configured operation mode.
Number of Connections per ServerNet Fabric Mismatch: The number of
connections per ServerNet fabric does not match with the configured
number.
Port Not Configured for CLIM: The p-switch is not configured to be
connected to a CLIM.
Unsupported Location: the configured location is not supported for
connection with a CLIM.
Unknown: The system is unable to determine the connection state of the
CLIM on this fabric.
The connectivity status of the CLIM to the ServerNet Y fabric. Displayed for
both Y1 and Y2 fabrics, provided the CLIM is configured for two connections
per ServerNet fabric. Possible values include:
Y1 Fabric Connection State
Y2 Fabric Connection State
Correctly Connected: The CLIM is correctly connected to the ServerNet Y
fabric.
Not Connected: The CLIM is not connected to the ServerNet Y fabric.
Location Mismatch: The CLIM is configured to be connected to a p-switch,
but is connected to a different port.
System Name Mismatch: The CLIM is configured with a system name that
does not match the name of the system to which it is connected.
Operation Mode Mismatch: The operation mode does not match with the
configured operation mode.
Number of Connections per ServerNet Fabric Mismatch: The number of
connections per ServerNet fabric does not match with the configured
number.
Port Not Configured for CLIM: The p-switch is not configured to be
connected to a CLIM.
Unsupported Location: the configured location is not supported for
connection with a CLIM.
Unknown: The system is unable to determine the connection state of the
CLIM on this fabric.
The DNS name of the Integrated Lights Out (iLO) on the CLIM.iLO DNS Name