• A new Place Local Node in Service action on the BladeCluster object, to be used when
intentionally halting a system to prevent all other directly-connected nodes from dialing out
an alarm as soon as SNETMON is stopped or the node is halted.
• Support for analyzing the system board battery sensor in RX2620, RX2660, RX2800 i2,
BL860c, and BL860c i2 servers at initial blade discovery and whenever the Save BMC Event
Log is retrieved (the default interval is every 24 hours). Upon detecting a battery that does not
meet performance requirements, OSM generates an alarm and dial-out to indicate that the
battery needs to be replaced.
• Support for invoking the CLIM iLO through the Invoke iLO action on the CLIM object even
when SNMP is not available. A new attribute on the CLIM object, iLO DNS Name, is also
displayed whether or not SNMP is available.
• These new configuration options, which are enabled through OSMCONF parameters, as
described in the OSM Configuration Guide:
◦ Suppression of alarms based on a specific problem and resource name.
◦ Support for having OSM bind to a specific IP address and TCP/IP stack, for OSM to use
when sending indications to the OSM Service Connection, HP Systems Insight Manager
or HP Insight Remote Support Advanced.
At H06.24/J06.13, OSM Service Connection (T0682 H02 ACV) added:
• Support for Core Licensing on HP Integrity NonStop NB54000c and NB54000c-CG
BladeSystems, including four new actions on the System object, two new attributes on the
Logical Processor object, and changes to the Save As System Load Configuration action on
the Disk, Disk (Fibre Channel), and CLIM-Attached Disk objects.
• Support for IPv6 (in addition to previous support for IPv4) on the operations and maintenance
LANs, including an OSMCONF file setting. For more information, see the OSM Configuration
Guide.
• Collect CLIM Logs action has been added to the CLIM object (was previously on just the CLIMs
object).
• A new Prepare for Down System CLIM Firmware Update action on the CLIMs object, to be
used in conjunction with the Down System CLIM Firmware Update Tool, a new component of
OSM Console Tools T0634 G06 ABB and later.
OSM Console Tools T0634 G06 ABB and later also includes the NonStop Maintenance LAN
DHCP DNS Configuration Wizard, which replaces the CLIM Boot Service Configuration Wizard.
It can be used to configure the DHCP and DNS servers required for NonStop J-series systems and
any NonStop systems with CLIMs attached.
For information on installing OSM Console Tools components, see the NonStop System Console
Installer Guide. For information on using the NonStop Maintenance LAN DHCP DNS Configuration
Wizard or the Down System CLIM Firmware Update Tool, see the online help available from within
those tools.
At H06.23/J06.12, OSM Service Connection (T0682 H02 ACN) added:
• Support for HP Integrity NonStop NS2200 series servers, including the new Processor Type
value of NSE-AD, as displayed in that attribute of the Logical Processor object.
• Support for Solid State Drives (SSDs) in D2700 Enclosures, including:
A Show SMARTSSD Wear Gauge action has been added to the SAS Disk object.◦
◦ A Media Type attribute has been added to the SAS Disk object to indicate whether the
disk is Magnetic or Solid State.
34