Verify Path B Access
Verifies that Path B from the FCDM via FC-AL I/O module B to the FCSA FSAC is responding.
FCDM Collection
The OSM Service Connection displays all Fibre Channel disk modules (FCDMs) within FCDM
Collection objects, whether or not they are daisy-chained. FCDMs that are daisy-chained together
(up to four) are displayed within the same FCDM Collection object. If an FCDM Collection object
contains only one FCDM, it is not daisy-chained. Other FCDMs that are not daisy-chained appear
under separate in FCDM Collection objects.
The FCDM Collection object appears within the same group object as the IOAM enclosure to which
the FCDM is connected. If the FCDM is connected to Fibre Channel ServerNet adapters located
in different IOAM enclosures (for increased fault tolerance), OSM displays the FCDM Collection
in the lower-numbered group.
For information on daisy-chaining FCDMs, see the NonStop NS-Series System Expansion and
Reduction Guide.
Location in OSM Tree: System > Group > FCDM Collection
Example: FCDM Collection (111.211)
Attributes
FCDM Collection
Displayed in the Attributes tab and Attributes dialog box only if the value is something
other than OK. Values
Service State
Path B
The location of FCSA connected to the disk drive through Port B.
Example: FCSA.FSAC-1.GRP-111.MOD-2.SLOT-1
Configured Controller
Location
Identifies the FCSA FSAC connected to the FCDM through Port B.
Example: FCSA FSAC (111.2.1.1)
Fibre Channel Controller
Path A
The location of FCSA connected to the disk drive through Port A.
Example: FCSA.FSAC-1.GRP-111.MOD-3.SLOT-1
Configured Controller
Location
Identifies the FCSA FSAC connected to the FCDM through Port A.
Example: FCSA FSAC (111.3.1.1)
Fibre Channel Controller
Actions
None.
FCSA
Fibre Channel ServerNet adapter. The FCSA object always displays two FCSA FSACs, regardless
of whether they are both physically present. At least one must be present to perform FCSA firmware
updates. The FCSA FSAC attributes Node Name and Port Name indicate the presence of FCSA
FSACs and attached disks. Unlike many other adapters, the ports on the FCSA are numbered from
top down when viewing the FCSA installed in a rack. Thus, FCSA FSAC 1 is attached to the upper
port (port 1) and FCSA FSAC 2 is attached to the lower port (port 2).
NOTE: If a ServerNet switch board is not present, FCSAs do not appear in OSM.