Attributes
Displayed in the Attributes tab and Attributes dialog box only if the value is
something other than OK. Values
Service State
Physical
The state of the fault LED on the fan.
Values: On, Off, Blinking
LED State
Whether the fan is installed and responding.
Values: Present, Absent, Unknown
Presence
Logical
The initial state of the component at the time of discovery.
Enabled: The component is operational.
Enabled State
Disabled: The component is present but not operational, possibly because
the Disable action was performed.
Indication of whether the fan has a fault.
Values: OK, Fault
Device State
Actions
Blink LED Off
Turns off the blinking of the fault LED.
Blink LED On
Causes the fault LED to start blinking.
Switch Group
A collection of up to four 6780 switches connected together, typically mounted in a rack, that
reside on one fabric of a cluster switch zone. The switch group is identified by a four-digit number.
The first two digits (10) distinguish a switch group from a group within a NonStop S-series server.
The third digit represents the zone number of the switch group, and the fourth digit indicates the
external ServerNet fabric where the switch group is located (0 for the X fabric and 1 for the Y
fabric).
Location in OSM tree: External ServerNet Fabric > Switch Group
Example: Switch Group 1020 (The switch group in zone 2 on the X fabric)
Attributes
Switch Group
Displayed in the Attributes tab and Attributes dialog box only if the value is
something other than OK. Values
Service State
Logical
Whether the switch group is installed and responding.
Values: Present, Absent, and Unknown
Presence