Siemens OSM Guía de usuario Pagina 171

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 306
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 170
Replace
Launches a documented service procedure to replace a NIC in a CLIM.
Optical Extender PIC
These (optional) Optical Extender PICs are used only in HP Integrity NonStop systems that include
VIO enclosures (represented in the OSM Service Connection as VIO modules). Optical Extender
PICs can be used as follows:
Slot 2 – for additional processor connectivity (processors 4 through 7) on NS14000 series,
NS1000, NS1200, NS2000 series, NS2100, NS2200 series, NS2300, and NS2400 series
servers.
Slot 3 for NonStop S-series connectivity on NS3000AC, or for CLIM connectivity on NS2000
series, NS2100, NS2200 series, NS2300, and NS2400 series servers.
Slot 4 – for CLIM connectivity on NS2000 series, NS2100, NS2200 series, NS2300, and
NS2400 series servers.
Slot 5 – for ServerNet cluster connectivity on NonStop NS14000 series servers.
Each Optical Extender PIC contains four ports.
NOTE: Optical Extender PICs are not a subcomponent of VIO modules in S-series servers.
For more information on ServerNet cluster connectivity for VIO enclosures, see the ServerNet Cluster
Supplement for NS-Series.
Location in OSM Tree: System > Fabric Group 100 > Internal ServerNet Fabric > VIO Module >
Optical Extender PIC
Example: Optical Extender PIC (100.2.2)
Attributes
Physical
A code that identifies the generation of the component. Hardware revision
codes are used for tracking components.
Hardware Revision
Indicates whether or not the Optical Extender PIC’s amber LED is lit. This
state is determined by the Set LED State action.
Value: On or Off
LED State
The part number of the component that was assigned in manufacturing. Use
part numbers for identifying and ordering parts.
Part Number
Indicates whether the component is powered on. ValuesPower State
A unique serial number that identifies the component. Track IDs are used for
tracking components.
Track ID
Identifies the type of ServerNet PIC.
Value: Optical Extender PIC
Type
Logical
The state of the component as known to the operating system on the server.
Values
Device State
Optical Extender PIC 171
Vista de pagina 170
1 2 ... 166 167 168 169 170 171 172 173 174 175 176 ... 305 306

Comentarios a estos manuales