E4SA (Ethernet 4 ServerNet Adapter)
An adapter that connects the ServerNet connections inside a server to an Ethernet local area
network (LAN). The Ethernet 4 ServerNet Adapter (E4SA) CRU contains two Ethernet ServerNet
addressable controllers (SACs), each of which contains two Ethernet physical interfaces, for a total
of four Ethernet ports on each E4SA CRU.
This Nonstop S-series component can be connected to a Nonstop NS-series system through an
IOMF2 enclosure.
Location in OSM Tree: System > Group > Module > E4SA
Slot Location: E4SA CRUs can be located in slots 51, 52, 53, and 54 in IOMF2 enclosures (service
side).
Example: E4SA $ZZLAN.E4SA0 (1.1.53)
Attributes
E4SA
Displayed in the Attributes tab and Attributes dialog box only if the value is something
other than OK. Values
Service State
Physical
A code that identifies the generation of the component. Hardware revision codes are
used for tracking components.
Hardware Revision
Identifies the manufacturer of the component.Manufacturer
The part number of the component that was assigned in manufacturing. Use part numbers
for identifying and ordering parts.
Part Number
Indication of whether the component is powered On or Off.Power State
A unique serial number that identifies the component. Track IDs are used for tracking
components.
Track ID
Logical
Which, if any, ServerNet router ports on this CRU are disabled. OSM actions to disable
or enable a ServerNet port are performed as directed by OSM alarm repair actions.
Disabled ServerNet Ports
The configuration type of this resource.
Value: CCSA, E4SA, FESA, G4SA, GESA, TRSA, Unknown
Configured Type
The state of the component as known to the operating system on the server. ValuesDevice State
Actions
Abort
Terminates operation of the Ethernet 4 ServerNet Adapter (E4SA) CRU and the associated Ethernet
ServerNet addressable controller (ESAC). When the Abort action finishes, the E4SA CRU and the
ESAC are in the Stopped state.
Disable ServerNet Port
Disables the specified ServerNet router port on this CRU. Perform this action only as directed by
OSM alarm repair actions.