following Reset, and perform the Reset to start running the new (non-BMC) firmware. Then you can
update the other image, which was the Running image but, following the Switch to Use Shadow...
and Reset actions, is now the Shadow image.
Switch to Use Running Firmware Image After Reset
Available for NonStop NS14000 series and NS16000 series servers only, this action sets the
NSBE Image After Next Reset attribute value to Running, indicating that the current Running firmware
image will be used after the next Reset action.
Blade Element Firmware
This object exists in OSM to display the many firmware attributes that exist for Integrity NonStop
NS14000 series and NS16000 series Blade Elements.
For these types of systems, the Blade Element firmware is updated through a guided procedure
launched by the Firmware Update action located under the Blade Complex object. For duplex or
triplex processor complexes, it is recommended that you update the Shadow image for all blade
elements in the complex at the same time, then reset the blade elements one at a time (using the
Reset Blade Element action under the Blade Elements object).
NOTE: For other Integrity NonStop servers, the firmware attributes valid for those systems are
displayed under the Blade Element Physical attributes instead, and the update procedure is launched
from a Firmware Update action located under the Blade Element object (rather than under the
Blade Complex object).
Attributes
Blade Element Firmware
NSBE represents NonStop Blade Element Firmware other than BMC. This
attribute indicates whether the current Shadow or Running firmware image
NSBE Image After Next Reset
will be used following the next Reset action, as specified by using the Switch
to Use Shadow or Running Firmware Image After Reset actions.
This attribute always displays a value of Running, because the Switch to Use
Shadow Firmware Image After Reset action immediately causes the Blade
BMC Image After Next Reset
Element to start running BMC firmware from the Shadow image. The Shadow
image at the time the action is performed immediately becomes the Running
image.
Halted State Services Firmware
The version of the HSS firmware currently running on the processor Blade
Element.
Running Version
The version of the HSS firmware currently designated as the Shadow image
of the Blade Element firmware.
Shadow Version
The name of the file to be used for a HSS firmware update.Default File Name
The version of the firmware to be used for a HSS firmware update.Default File Version
The difference, if any, between the current Running image and default HSS
firmware version. Values
Running Compare State
The difference, if any, between the current Shadow image and default HSS
firmware version. Values
Shadow Compare State