Soft Reset
Reinitializes the firmware without affecting the ServerNet Switch hardware or the routing tables.
Synchronize FIR Files to Other Switches
Synchronizes the FRU information record (FIR) files of the X and Y fabric ServerNet switches. The
files will be synchronized from the switch on which this action is executed to the other switch.
ServerNet Switch Board
A component of both the IOAM and Processor Switch, the ServerNet Switch Board provides
ServerNet connectivity between processors, ServerNet adapters, and attached hardware devices.
OSM software communicates with an internal part of the switch known as the Maintenance Entity
(ME) by a connection established through the Maintenance Switch.
While always named ServerNet Switch Board in the OSM tree pane, the Multi-Resource Actions
dialog box uses unique names to differentiate between the different types:
A ServerNet Switch Board in a processor switch module is displayed as a Processor ServerNet
Switch Board.
An IOAM ServerNet Switch Board in an HP Integrity NonStop NS16000 series server is
displayed as a ServerNet Switch Board.
An IOAM ServerNet Switch Board in an HP Integrity NonStop NS14000 or NS1000 server
(which has no processor switches), is displayed as an IO/Switch Board.
Location in OSM Tree:
In an IOAM: System > Group > IOAM Enclosure > IOAM > ServerNet Switch Board
Examples:
In an Integrity NonStop NS16000 series server: ServerNet Switch Board (110.2.14)
In an Integrity NonStop NS14000 or NS1000 server: ServerNet Switch Board (100.2.14)
In a Processor Switch: System > Fabric Group > Internal ServerNet Fabric > Processor Switch >
ServerNet Switch Board
Example: ServerNet Switch Board (110.2.14)
Attributes
ServerNet Switch Board
Displayed in the Attributes tab and Attributes dialog box only if the value is
something other than OK. Values
Service State
Physical
A code that identifies the generation of the component. Hardware revision
codes are used for tracking components.
Hardware Revision
Indicates whether the ServerNet Switch Board LED is on or off.LED State
The part number of the component that was assigned in manufacturing. Use
part numbers for identifying and ordering parts.
Part Number
A unique serial number that identifies the component. Track IDs are used for
tracking components.
Track ID