SCF Equivalent: SCF ALTER SWITCH $ZZSMN, NEAREST { X | Y}, BLINK NONE
Blink LED On
Causes the LED to start blinking.
SCF Equivalent: SCF ALTER SWITCH $ZZSMN, NEAREST { X | Y}, BLINK ALL
Configuration Update
This action updates the configuration for the ServerNet II switch component of the 6770 switch
module. For more information, see Updating Cluster Switches.
NOTE: If you are updating both firmware and configuration on the same cluster switch, you
should always update the firmware first. In some circumstances, updating both firmware and
configuration is not necessary. For more information, see the ServerNet Cluster Manual.
Optional Parameter: File name of the configuration file.
Firmware Update
Updates the firmware on the ServerNet II switch component of the 6770 switch module. For more
information, see Updating Cluster Switches.
Optional Parameter: File name of the firmware file.
Hard Reset
Is necessary following a Configuration Update action in order for the changes to take effect.
CAUTION: This action disrupts the ServerNet traffic through this switch.
SCF Equivalent: SCF RESET SWITCH $ZZSMN, NEAREST { X | Y }, HARD
Prepare to Replace
Must be performed from each node of a ServerNet cluster before replacing a ServerNet II Switch
for SANMAN to accept the new switch.
Replace
Launches the guided procedure for replacing a ServerNet II Switch.
Set Fabric Setting
Sets the fabric LED indicator for the ServerNet II Switch to either X or Y.
Within three minutes after the action completes, the SANMAN process running on each of the
nodes discovers that the fabric setting has been corrected and accepts the new switch.
Parameter: Fabric Setting can be set to Unknown, Clear, X,or Y.
SCF Equivalent: SCF ALTER SWITCH $ZZSMN, NEAREST { X | Y }, FABRIC { X| Y }
Soft Reset
Used following a Firmware Update action on the switch for the changes to take effect.
SCF Equivalent: SCF RESET SWITCH $ZZSMN, NEAREST { X | Y }, SOFT
Switch Fan
A component that circulates air into the enclosure to help maintain optimal temperature.
Location in OSM tree: External ServerNet Fabric > Switch Group > Switch Module > Switch Fan
Example: Fan (1020.1.16)
Switch Fan 267