IP 266 Machine Data, Modes and Traversing Programs
5.2 Modes and How to Invoke Them
The IP 266 provides a large variety of options for positioning, coordinate shifting
and positional corrections. These options are grouped under the term "modes".
The available modes can be divided into the two basic categories
open-loop positioning and
closed-loop positioning
Table 5-4 lists the modes belonging to each of these two categories.
Table 5-4. Positioning Modes with and without Position Control
Positioning Modes
Without position control With position control
Bring coordinate
system to a
defined state
Command-
initiated for-
ward/reverse
travel
Approach to a
specific target
position; tra-
versing a spe-
cific distance
Output of a
constant speed
setpoint
Setpoint output
= 0 V + drift
voltage
Controlled jog Follow-up mode Increment
mode absolute
Increment
mode relative
Automatic
mode
Automatic
single block
mode
Jog 1
Jog 2
Approach to
reference point
In addition to the modes listed above, a number of information modes are also
available. These include modes 71 to 73, which provide information on the status
and position of the drive.